AP 8KW-20KW 120V/240V 
Dual Output

Low Frequency Pure Sine Wave Inverter/Charger

off-grid / DC 12V 24V 48V 96V / AC 120V 240V dual output

Pure sine wave output. THD <3%. The conventional conversion time is 6ms. It can hold 300% overload within 20s, providing necessary current for starting electrical appliances with high requirements. HP series is capable of starting and stopping the generator, and realizing the function of monitoring the equipment operation status and battery temperature etc.by mobile through additional communication modules.

Product Features

  • 图标-20497
    THD<3% under standard load
  • 215-05951
    Multiple protection for safer use
  • 图标-14w0z
    Switch time <8 m
    (to off grid mode)

  • 图标-15npj
    Generator automatic start/stop function

Application

AP 8-12KW应用图-01

Basic application

The system can use PV energy to power loads when grid is unavailable, minimizing the use of generator. Excessed PV energy can be stored in batteries and provide backup power during outages. Compensating with a generator to avoid power shortage issue.

AP 8-12KW应用图-02

Backup power scheme

It can be used as a stable and reliable backup power source, using photovoltaic energy to charge the batteries and seamlessly switching to standby mode in milliseconds to power critical equipment in the event of a grid failure. Coupled with a generator, it is possible to increase the amount of time spent off-grid at night.

  • Technical Parameter

    +
    AP 8KW-20KW Pure Sine Wave Inverter & Charger
    Inverter
    Output
    Model 8.0KW 10.0KW 12.0KW 15.0KW 18.0KW 20.0KW
    Continuous Output Power 8.0KW 10.0KW 12.0KW 15.0KW 18.0KW 20.0KW
    Surge Rating (20Secs) 24.0KW 30.0KW 36.0KW 45.0KW 54.0KW 60.0KW
    Output Waveform Pure Sine vave/Same as input (Bypass Mode)
    Nominal Efficiency >88% (Peak)
    Line Mode Efficiency >95%
    Power Factor 0.9-1.0
    Nominal Output Voltage 220-230-240Vac
    Output Voltage Regulation ±10%RMS
    Output Frequency 50Hz±0.3Hz / 60Hz±0.3Hz
    Short Circuit Protection Yes (1 sec after fault)
    Typical transfer Time 10ms (Max)
    THD < 3% (Rated battery level, rated full linear load)
    DC Input Nominal Input Voltage 24.0Vdc/48.0Vdc/96.0Vdc 48.0Vdc/96.0Vdc
    Minimum Start Voltage 10.0Vdc / 10.5Vdc for 12Vdc Mode *2 for 24Vdc/*4 for 48Vdc/*8 for 96Vdc
    Low Battery Alarm 10.5Vdc / 11.0Vdc for 12Vdc Mode
    Low Batteiy Trip 10.0Vdc / 10.5Vdc for 12Vdc Mode
    High Voltage Alarm 16.0Vdc for 12Vdc Mode
    Low Battery Voltage Recover 15.5Vdc for 12Vdc Mode
    ldle Consumption-Search Mode < 25W When Power Saver On
    Charger Output Voltage Depends on battery type
    Charger Breaker Rating 50A 80A 80A 100A
    Battery Initial Voltage for start 10-15.7Vdc for 12Vdc Mode *2 for 24Vdc / 4 for 48Vdc/ 8 for 96Vdc
    Over Charge Protection S.D 15.7Vdc for 12Vdc Mode
    Selector Switch Setting Description Fast Mode / VDC Float Mode / VDC
    0 Charger Off
    1 Gel USA 14 13.7
    2 AGM 1 14.1 13.4
    3 Lithium 13.8 13.6
    4 Sealed Lead Acid 14.4 13.6
    5 Gel EURO 14.4 13.8
    6 Open Lead Acid 14.8 13.8
    7 LifePO4 14 13.8
    8 De-sulphation 15.5 (4 Hours then Off)
    9 Classic LFP 13.6 13.5
    For 12Vdc Mode Series(*2 for 24Vdc Mode/*4 for 48Vdc Mode/*8 for 96Vdc Mode)
    BTS Battery Temperature Sensor
    (Optional)
    Yes ( Refer to the table) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature
    Bypass &
    Protection
    Input Voltage Waveform Sine vave (Grid or Generator)
    Nominal Voltage 220-230-240Vac
    Max Input AC Voltage 300Vac For 230Vac HV Mode
    Nominal Input Frequency 50Hz or 60Hz
    Low Freq Trip 47±0.3Hz for 50Hz,57±0.3Hz for 60Hz
    High Freq Tip 55±0.3Hz for 50Hz,65±0.3Hz for 60Hz
    Over Load Protection
    (SMPS  load)
    Circuit Breaker
    Output Short Circuit Protection Circuit Breaker
    By pass Breaker Rating 50A 80A 80A 100A
    Transfer SWitch Rating 80AmpforUL&TUV 100Amp for UL
    Bypass Without Battery
    Connected
    Yes (Optional)
    Max Bypass Current 80 Amp 100Amp
    Mechanical
    Specifications
    Mounting Wall Mount
    Inverter Dimensions (L*W*H) 588*415*200mm 706*415*213mm
    Inverter Weight KG 60 66 70 85 95 100
    Shipping Dimensions(L*W*H) 750*520*310mm 850*520*350mm
    Shipping Weight KG 62 68 72 87 97 102
    Display Status LEDs / Status LEDs+LCD
    Standard Warranty 1 Year