Leave Your Message
您的浏览器版本不支持canvas
Off Grid inverter
Off Grid inverter
Off Grid inverter
Off Grid inverter
Off Grid inverter
0102030405

HP-W 1KW-20KW

Low Frequency Pure Sine Wave Inverter/Charger

built-in EMS / off-grid / DC 48V / AC 230V

Built-in EMS, achieves high efficient utilization of power energy between the grid and battery.IP20 protection.Ultra low THD, typically 7% under full linear load (battery low).Battery temperature sensing for increased charging precision.
Powerful charge rate up to 120 Amp, selectable from 0%-100%.Auto Gen Start function for off grid system with generator as backup power.PF1.0, high efficiency, lower consumption.

No power grid:

when the battery voltage reaches the low voltage,Pv and generator to charge the battery and power the loads,the max AC charging current up to 140A,so the charging speed is very fast. When the battery is fully charged,it supplies power to the load together.

Therefore, solar off grid energy storage systems are suitable for the following situations:

ldeal for areas with no power grid:If you live in an area without power grid,solar off-grid energy storage system are a great choice as you're generating your own electricity.


An off-grid inverter 230V is a specific type of inverter designed for off-grid energy systems to convert direct current (DC) from batteries or solar panels into alternating current (AC) with a standard output voltage of 230V, which is widely used in residential and commercial applications in regions with this voltage standard. It operates independently of the utility grid, enabling energy systems to function in remote locations or during power outages. These inverters typically feature advanced technologies like pure sine wave output to ensure compatibility with sensitive electronics, battery management systems to optimize charging and discharging, and smart monitoring capabilities for real-time performance tracking. They often include safety features such as overvoltage, undervoltage, short circuit, and over-temperature protection. An off-grid inverter 230V is ideal for powering household appliances, industrial equipment, and even entire buildings, making it a key component of reliable and sustainable off-grid energy solutions.

Product Features

  • 215-027cq
    Built-in EMS management system
  • 图标-20497
    THD<3% under standard load
  • 215-05951
    Multiple protection for safer use
  • 图标-14w0z
    Switch time <8 m
    (to off grid mode)

  • 图标-15npj
    Generator automatic start/stop function

Application

Off Grid inverter

Off-Grid System

Designed for areas without grid access or the grid is unstable, this system provides reliable power through energy storage and smart controls. It stores excess energy when available and switches to off-grid mode during outages, ensuring key devices stay operational. Ideal for remote locations or high-reliability power needs.

  • Technical Parameter

    +
    HP-W Pure Sine Wave Inverterl Charger
    Inverter Output
    Model 1.0KW 1.5KW 2.0KW 3.0KW 4.0KW 5.0KW 6.0KW 8.0KW 10.0KW 12.0KW 15.0KW 18.0KW 20.0KW
    Continuous Output Power 1.0KW 1.5KW 2.0KW 3.0KW 4.0KW 5.0KW 6.0KW 8.0KW 10.0KW 12.0KW 15.0KW 18.0KW 20.0KW
    Surge Rating (20Secs) 3.0KW 4.5KW 6.0KW 9.0KW 12.0KW 15.0KW 18.0KW 24.0KW 30.0KW 36.0KW 45.0KW 54.0KW 60.0KW
    Output Waveform Pure Sine wave/Same as input(Bypass Mode)
    Max. Efficiency 92%
    Line Mode Efficiency >95%
    Power Factor 0.9-1.0
    Nominal Output Voltage 100-110-120Vac/220-230-240Vac
    Output Voltage Regulation ±10%RMS
    Output Frequency 50Hz±0.3Hz/60Hz±0.3Hz
    Short Circuit Protection Yes(1 sec after fault)
    Typical transfer Time 10ms(Max)
    THD <3%(Rated battery level,rated full linear load)
    DC Input
    Nominal Input Voltage 12.0Vdc/24.0Vdc    12.0Vdc/24.0Vdc/48.0Vdc 24.0Vdc
    48.0Vdc
    24.0Vdc/48.0Vdc/96.0Vdc 48.0Vdc/96.0Vdc
    Minimum Start Voltage 10.0Vdc/10.5Vdc for 12Vdc Mode *2 for 24Vdc/*4 for 48Vdc/*8 for 96Vdc,
    Low Battery Alarm 10.5Vdc/11.0Vdc for 12Vdc Mode
    Low Batteiy Trip 10.0Vdc 10.5Vdc for 12Vdc Mode
    High Voltage Alarm 16.0Vdc for12Vdc Mode
    Low Battery Voltage Recover 15.5Vdc for 12Vdc Mode
    ldle Consumption-Search Mode <25W When Power Saver On
    Charger
    Output Voltage Depends on battery type 
    Charger Breaker Rating 20A 20A 20A 25A 32A 40A 40A 50A 80A 80A 100A
    Battery Initial Voltage for start 10-15.7Vdc for 12Vdc Mode *2 for 24Vdc,4 for 48Vdc/*8 for 96Vdc,
    Over Charge Protection S.D 15.7Vdc for 12Vdc Mode
    Selector Switch Setting Description Fast Mode/VDC Float Mode/VDC
    Charger Off
    Gel USA 14.0  13.7 
    AGM 1 14.1  13.4 
    Lithium 13.8  13.6 
    Sealed Lead Acid 14.4  13.6 
    Gel EURO 14.4  13.8 
    Open Lead Acid 14.8  13.8 
    LifePO4 14.0  13.8 
    De-sulphation 15.5(4 Hours then Off)
    Classic LFP 13.6  13.5 
    For 12Vdc Mode Series(*2 for 24Vdc Mode/*4 for 48Vdc Mode/*8 for 96Vdc Mode)
    BTS
    Battery Temperature Sensor
    (Optional)
    Yes(Refer to the table)Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature.
    Bypass & Protection
    Input Voltage Waveform Sine wave (Grid or Generaton)
    Nominal Voltage 100-110-120Vac/220-230-240Vac
    Max Input AC Voltage 150Vac For 120Vac LV Mode;300Vac For 230Vac HV Mode
    Nominal Input Frequency 50Hz or 60Hz
    Low Freq Trip 47±0.3Hz for 50Hz 57±0.3Hz for 60Hz
    High Freq Tip 55±0.3Hz for 50Hz.65+0.3Hz for 60Hz
    Over Load Protection (SMPS  load) Circuit Breaker
    Output Short Circuit Protection Circuit Breaker
    By pass Breaker Rating 20A  20A 20A 25A 32A 40A  40A 50A 80A 80A 100A
    Transfer SWitch Rating 30AmpforUL&TUV 40Ampfor UL 80Amp for UL 100Amp forUL
    Bypass Without Battery
    Connected
    Yes (Optional)
    Max Bypass Current 30Amp 40Amp 80Amp 100 Amp
    Mechanical Specifications
    Mounting Wall Mount
    Inverter Dimensions (L*W*H) 388*415*200mm 390*192*567mm 400*192*675mm 415*213*706mm
    Display Status LEDs /Status LEDs+LCD
    Standard Warranty 1 Year

Related Products

WHAT CAN WE DO FOR YOU

Your Name*

Phone Number

Country

Remarks*

您的浏览器版本不支持canvas
reset