OPS 600W-1500W 120V

High Frequency Inverter

input DC 12V 24V / output AC 110V 115V 120V

High frequency pure sine wave output, high power density, reliable performance. 200% surge capacity.

How High-Frequency Inverters Work:

1.Input Stage (DC-DC Conversion):

The DC input is processed and adjusted to the desired level using a DC-DC converter.

2.Inversion Stage (DC-AC Conversion):

High-frequency switches rapidly alternate the polarity of the DC voltage to create an AC waveform.

3.Filtering:

The high-frequency signal is filtered to remove noise and generate a smooth AC output.

4.Control and Monitoring:

A microcontroller or digital signal processor (DSP) ensures the inverter maintains the desired frequency, waveform, and output quality.


Solar Power Systems: Converts DC power from solar panels into AC power for use in homes and businesses.

Uninterruptible Power Supplies (UPS): Used in backup systems to convert DC battery power into AC electricity during power outages.

Electric Vehicles (EVs): Inverters in EVs convert DC from the battery into AC to power the motor.

Off-Grid Systems: Provides AC power in off-grid locations, converting stored DC energy from batteries into usable AC for appliances and lighting.

Product Features

  • 215-027cq
    Built-in EMS management system
  • 图标-20497
    THD<3% under standard load
  • 215-05951
    Multiple protection for safer use
  • 图标-14w0z
    Switch time <8 m
    (to off grid mode)

  • 图标-15npj
    Generator automatic start/stop function

Optional Output Socket

  • Technical Parameter

    +

    OPS 600W-1500W Pure Sine Wave Inverter
    Input Item 612 1012 0612E 1012E
    624 1024 1524 0624E 1024E 1524E
    Nominal voltage 12Vdc(*2 for 24Vdc)
    Operating range 10Vdc~15.1Vdc
    Startup voltage 11.75Vdc~14.8Vdc
    Load Level 0-29% 30-69% 70-100%
    Battery alarm level Battery-low Level 11.3Vdc 11.2Vdc 11.0Vdc
    Battery-high Level 14.1Vdc 14.0Vdc 13.8Vdc
    Battery
    shut-down level
    Battery-under Level 10.3Vdc 10.2Vdc 10.0Vdc
    Battery-over Level 15.1Vdc 15.0Vdc 14.8Vdc
    Battery
    recovery level
    Battery-under Recovery 12.5Vdc
    Battery-over Recovery 14.0Vdc
    Output Output Waveform Pure sine wave
    Output Power 600W 1000W 1500W 600W 1000W 1500W
    Surge Rating 2*Prated
    Nominal Output
    Voltage
    110/115/120Vac 220/230/240Vac
    Output Voltage
    Regulation
    ± 5%......when input voltage higher than battery-low level
    Output Frequency 50/60Hz±0.1%
    Output Current
    @ 220/230/240
    2.73A /
     2.61A /
    2.50A
    4.55A /
    4.35A /
    4.17A
    6.81A /
    6.52A /
    6.25A
    Output Current
    @110/115/120
    5.45A /
    5.22A /
    5A
    9.09A /
    8.70A /
    8.33A
    13.63A / 13.04A / 12.50A
    Crest factor 3:01
    THD <3%. linear load; <5%. non-linear load....at nominal Input voltage
    <15%..........................................................at minimum cut-off (10Vdc) level
    Peak Output Current
    @ 220/230/240
    5.45A /
    5.22A /
    5A
    9.09A /
    8.70A /
    8.33A
    13.63A / 13.04A / 12.50A
    Peak Output Current @110/115/120 10.92A /
    10.44A /
    10A
    182A /
    17.4A /
    16.68A
    27.3A /
    26.1A /
    25A
    Efficiency >88% (typical), 90% (peak)
    No load
    Current Draw
    <15W <15W <15W <20W <20W <20W
    Stand-by
    Current Draw
    <6W <6W <6W <6W <6W <6W
    Over load protection Refer to Sec.3.9 and Sec.3.10
    Environmental Noise <50 dB
    Operating temperature Operation temperature: -20 to +70°C,-5 to +40 °C with full performance
    Storage temperature ‘-30-70°C
    Operating humidity 90% RH (no condense)
    Operating Attitude 1500m
    Safety ETL, UL-458, CE
    EMC FCC Part 15 Class B. EN55022 Class B. E-mark
    Mechanical Dimension LxWxH(mm) 270x160x70 mm 355x190x95 mm 270x160x70 mm 355x190x95 mm
    Weight (Kg) 2.5kg 4.0Kg 4.5kg 2.5kg 4.0Kg 4.5kg
    Force cooling Load and Temperature Controlled Cooling Fan
    Control Protection Overload, Short circuits, Reverse polarity. Over/ under input voltage, Over temperature, High output voltage, Low output voltage, Unit internal failure. Unit in-parallel failure
    Startup time < 5 Seconds
    Power Saving
    Recovery Time
    5 Seconds
    Human
    Interface
    LED Indicator 3-LED installed
    Audible Alarm Buzzer
    Communication
    Interface
    RS232