Leave Your Message
您的浏览器版本不支持canvas
Three Phase Off Grid inverter
Three Phase Off Grid inverter
Three Phase Off Grid inverter
010203

TP-3 36KW Three Phase

Off Grid Hybrid Inverter Charger

three phase / off-grid / DC 48V / AC 400V

Three phase pure sine wave output. The conventional conversion time is 8ms. Designed for harsh environment. It can hold 300% overload within 20s, providing necessary current for starting electrical appliances with high requirements. TPP series is capable of starting and stopping the generator, and realizing the function of monitoring the equipment operation status and battery temperature etc.by mobile through additional communication modules.


Three-phase pure sine wave inverter/chargers are widely used across diverse sectors:

1.Industrial Facilities:

Powers heavy machinery and equipment that require stable three-phase power.

2.Renewable Energy Systems:

Integrates with solar or wind power systems to store and manage renewable energy efficiently.

3.Commercial Buildings:

Supports HVAC systems, lighting, and other critical loads.

4.Off-Grid and Backup Power Systems:

Provides reliable energy storage and conversion in remote locations or during power outages.

Product Features

  • 图标-20497
    THD<3% under standard load
  • 215-05951
    Multiple protection for safer use
  • 图标-14w0z
    Switch time <8 m
    (to off grid mode)

  • 图标-15npj
    Generator automatic start/stop function

Application

Three Phase Off Grid inverter

Basic application

The system can use PV energy to power loads when grid is unavailable, minimizing the use of generator. Excessed PV energy can be stored in batteries and provide backup power during outages. Compensating with a generator to avoid power shortage issue.

Three Phase Off Grid inverter

Backup power scheme

It can be used as a stable and reliable backup power source, using photovoltaic energy to charge the batteries and seamlessly switching to standby mode in milliseconds to power critical equipment in the event of a grid failure. Coupled with a generator, it is possible to increase the amount of time spent off-grid at night.

  • Technical Parameter

    +

    TP-3 Series Off Grid Three Phase Hybrid Inverter Charger
    Inverter
    Output
    Model 36KW
    Continuous Output Power 36000W
    Surge Rating(20s) 108000W
    Capable of Starting Electric Motor 36HP
    Unbalance Load Acceptable 100%
    DC Input Voltage 48Vdc
    Output Waveform Pure Sine wave/Same as input (Bypass mode)
    Nominal Efficiency 89% (Peak)
    Line Mode Efficiency >95%
    Power Factor 0.9-1.0
    Connection Mode 3-phase 4-wire system+Grid
    Output Voltage Rating 400V
    Output Phase Voltage 230Vac
    Output Voltage Regulation ±10% RMS
    Output Frequency 50/60Hz ± 0.3Hz
    Short Circuit Protection Yes, current limit function (Fault after 60ms)
    Typical Transfer Time Typical 6~8ms,10ms (Max)
    THD <3% linear load
    DC Input Nominal Input Voltage 48Vdc
    Min. Start Voltage 42Vdc / 44Vdc
    Low Battery Alarm 42Vdc / 44Vdc
    Low Battery Trip 40Vdc / 42Vdc
    High Voltage Alarm & Fault 64Vdc
    High DC Input Recovery 62Vdc
    Low Battery Voltage Recover 52Vdc
    Idle Consumption-Search Mode < 100W(When power saver on)
    Charge Input Voltage Range Narrow: 96~132Vac/ 184~253Vac ; Wide:70~135Vac / 140~270Vac
    Input Frequency Range Narrow: 47-55±0.3Hz for 50Hz,57-65±0.3Hz for 60Hz 
    Wide: 40-70±0.3Hz for 50Hz/60Hz
    Output Voltage Same as input
    Charger Breaker Rating(230Vac) 60A
    Charger Breaker Rating(120Vac) /

Related Products

WHAT CAN WE DO FOR YOU

Your Name*

Phone Number

Country

Remarks*

您的浏览器版本不支持canvas
reset